Fuser temp low. Heat lamp,
|
Код ошибки |
Описание |
|
E000 |
Fuser temp low. Heat lamp, thermoswitch, thermistor, SSR |
|
E001 |
Fuser temperature too high or shorted thermistor |
|
E002 |
Fuser temperature too low |
|
E003 |
Fuser temperature too low |
|
E004 |
SSR, or lamp reg. board |
|
E010 |
Drive problem |
|
E022 |
DV unit switching problem |
|
E030 |
Counter not working/open |
|
E202 |
Scan problem. Scan sensor, scan motor |
|
E204 |
Scan problem. Scan sensor, scan motor |
|
E210 |
Lens problem. Lens sensor, lens motor |
|
E220 |
Exposure lamp |
|
E240 |
DC controller (main board) |
|
E400 |
RDF circuit board |
|
E401 |
RDF pickup motor drive |
|
E402 |
RDF belt motor drive |
|
E403 |
RDF feed drive problem |
|
E404 |
RDF exit motor |
|
E411 |
RDF sensor problem |
|
E500 |
Sorter board problem |
|
E510 |
Sorter feed motor |
|
E512 |
Sorter delivery motor |
|
E514 |
Sorter delivery motor |
|
E520 |
Sort stack motor |
|
E530 |
Vibrator motor |
|
E531 |
Stapler motor |
|
E535 |
Vibrator motor |
|
E540 |
Shift problem |
|
E541 |
Shift problem |
|
E710 |
DC controller |
|
E711 |
DC controller |
|
E712 |
DC controller. Document feeder board or cable |
|
E800 |
Auto shut off relay |