F.A.Q. по ремонту и обслуживанию копиров

Frequency monitoring and zero cross




Код ошибки

Описание

01-01

Frequency monitoring and zero cross problem

01-02

Interlock

01-03

AC power problem

01-04

Finisher interlock

01-05

24v problem

03-01

Optics to main board communication problem

03-02

Software reset problem

03-03

Could be punched holes in the lead edge of the original

03-04

Software problem

03-06

Low battery

03-07

NVM not initialized or is missing or defective

03-17

Communication problem between main board and finisher board

03-18

Initializes one NVM counter to agree to others

03-19

All three NVM counter to agree with others

03-20

Main board/interface board problems

03-21

Problem with RIC NVM

03-22

RIC modem problem

03-23

RIC real time clock failure.

03-25

RIC NVM problem or not initialized

03-27

NVM problem

03-28

Watchdog software problem

03-29

Microprocessor crystal not at correct frequency

03-30

No software response from finisher after 20 seconds have elapsed

06-01

Lens did not reach 1.1 position

06-02

1/2 rate scanner problem

06-03

Scan home problem

06-04

Scan home problem

06-05

Scan home problem

06-06

Scan encoder

06-07

Scan encoder

06-08

Scan drive boost

06-09

Scan encoder

06-11

Scan encoder pulse phases

06-12

Insufficient scan damping

07-01

Duplex tray not home during duplexing

07-02

Tray 2 not home when selected

07-13

Tray 2 height sensor problem

07-15

Tray 2 empty

07-16

Tray 1 door open

07-18

Tray 1 stack sensor

07-22

Tray 1 empty

07-26

Tray 1 bypass switch actuated too long

07-27

Tray 1 bypass switch deactuated too early

07-30

Paper in duplex

07-31

Paper in duplex

07-32

Duplex tray empty, when paper should be there

08-10

Paper did not reach tray 2 input tray sensor

08-11

Paper did not reach duplex input sensor

08-12

Paper did not reach tray 1

08-14

Paper did not leave tray 2 input sensor quickly enough

08-18

Trail edge did not reach tray 2 input sensor quickly enough

08-19

Trail edge did not reach tray 1 input sensor quickly enough

08-20

Paper in duplex

08-21

Paper in tray 2 input

08-22

Paper in tray 2 or duplex at wrong time

08-23

Paper at tray 1 input at wrong time

08-24

Paper in tray 1 at wrong time

08-28

Upper and lower nips problem

09-08

Low toner condition

09-12

Drum signals are out of range

09-13

Unstable drum patch readings

09-15

Patch is too dark

09-16

Patch is too light

09-17

Open toner container access cover

09-18

Low toner level

09-21

Low toner sensor disconnected

09-22

Low toner condition, even after machine has been theoretically, adding toner

10-02

Low fuser temperature

10-03

High fuser temperature

10-06

Paper did not reach out put switch

10-07

Paper stayed on output switch

10-10

Paper did not reach decurler sensor

10-11

Paper did not reach decurler sensor

10-12

Paper on decurler sensor

10-13

Paper did not reach duplex entry sensor in time

10-14

Paper did not reach duplex entry sensor in time

10-15

Paper on entry sensor at wrong time

10-17

Fuser temperature is too high and fuser relay has deactuated

12-01

Paper at finisher input sensor

12-02

Paper did not reach finisher

12-03

Paper reached finisher too soon

12-05

Paper at stapler

12-06

Paper at stapler

12-07

Paper did not reach stapler

12-08

Paper did not reach stapler

12-10

Complied motor not working properly

12-15

Eject motor problem and/or eject encoder

12-20

Stacker motor problem

12-21

Stacker interlock

12-22

Stacker bottom sensor

12-23

Stacker bottom sensor

12-24

Stacker bottom sensor senses full

12-25

Stack height sensor

12-26

Stack height sensor

12-27

Stack height sensor

12-30

Offset home sensor

12-31

Offset home sensor

12-32

OCT switch

12-35

Eject nip carriage

12-36

Eject cam interlock

12-37

Eject nip carriage open timing

12-38

Eject cam interlock

12-40

Tamper motor

12-41

Tamper home problem

12-42

Tamper home sensor

12-43

Staple load sensor

12-44

Tamper home sensor

12-45

Tamper home sensor

12-50

Low on staples

12-51

Stapler home sensor

12-52

Stapler home sensor

12-53

Eject cam interlock

33-37

Too few documents

55-01

rdh interlock switch open during use

55-04

Paper on bypass sensor

55-05

Paper at vacuum timing sensor

55-06

Paper on output sensor

55-10

No paper reached S31

55-20

Paper did not leave S31 at correct time

55-24

Set counter arm problem

55-25

Documents in input tray not detected

55-27

Lead edge did not reach S35 at correct time

55-2955-30

Trail edge did not reach S35 at correct time

55-31

S32, ADF registration sensor did not see paper at correct time

55-32

S32 did not see trail edge at correct time

55-33

S36 One too many documents

55-36

One too many documents

55-39

Hole count problem on document feeder belt

55-40

Document belt travel problem

55-41

Document belt mistracking or skewing

55-45

Paper at inverter sensor

55-47

Inverter sensor did not see paper lead edge at correct time

55-49

More than 50 sheets in input tray

55-50

Right side interlock

55-51

Left side interlock

55-55

Document on glass

93-93

NVM has to be initialized after new software installed